BPIT, Inc. - Ignition Lances

Ignition Lances

By: Durag


Connection to ignition devices for
the ignition of gas or liquid fuels in industrial burners of any capacity.


BPIT, Inc. - Quotation icon Get a quote »



Features:

  • Ignition tip temperature-proof up to 600°C,
    up to 800°C for a short period
  • High-temperature model temperature-proof
    up to 1000°C.

Applications:

  • Chemical industry
  • Refineries
  • Cement plants
  • Waste incinerators
  • Steam generators
  • Heating plants
  • Claus plants

Specifications:

D-ZL 441 Ex: Hazardous area ignition lance for use with D-HG 400-54 Ex or D-HG 400-72 Ex
Cable length L1: min. 1 m, max. 50 m,
Cable off-take angle at the lance: 0° or 90°
Lance length L2: min. 0.7 m, max. 15 m;
separations required for L2>4m
Cable weight: 0,5 kg + 0,5 kg/m
Lance weight: 1.6 kg/m at Ø22 mm
ATEX Certificate: PTB 11 ATEX 1004 X
Explosion protection: II 2G Ex d IIC T6, T5, and T4 Gb
II 2D Ex tb IIIC T80, 95, and 130°C Db IP65
Ambient Temperature: -40°C to +80°C
   
D-ZL 421: Separated ignition lance for D-HG 400-65
Cable off-take at the device: 0° or 90°
Cable length L1: min. 1 m, max. 50 m,
Cable off-take at the lance: 0° or 90°
Lance length L2: min. 0,7 m, max. 15 m
separations required for L2>4m
Cable weight: 0.5 kg + 0.5 kg/m
Lance weight: 1,6 kg/m at Ø22 mm

* For more detailed specification, please contact BP Integrated Technologies, Inc.